|
ISO 9001:2000 Registered |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
PVC PRESSURE PIPE Northern Pipe Products PVC AWWA C-900 PVC Pressure Pipe is manufactured from compounds conforming to PVC cell classification of 12454B as defined in ASTM D-1784. The pipe meets the requirements of the AWWA C-900 standard specification for polyvinyl chloride water distribution pipe. The integral bell joint system meets the requirements of ASTM D-3139 and utilizes an elastomeric seal conforming to ASTM F-477. Northern Pipe Products AWWA C-900 Pressure Pipe for potable water carries the NSF Standard 61, the Canadian Standards Association Standard B137.3, the Underwriters Laboratories Inc Standard 1285, the Underwriters Laboratories of Canada Standard ULC/ORD-C1285, and the Factory Mutual Research Water Distribution Pipe for Underground Fire Protection Service marks of acceptance. The pipe is furnished in 20-foot laying lengths. The spigot ends are beveled and insertion depths are marked for correct installation. AWWA C-900 Potable Water Pipe Nominal Pipe Size Inches DR-25 DR-18 DR-14 Min. Min. Wall Inches Min. Wall Inches 4 4.800 .192 1.87 .267 2.55 .343 3.22 6 6.900 .276 3.90 .383 5.29 .493 6.70 8 9.050 .362 6.69 .503 9.15 .646 11.55 10 11.100 .444 10.11 .617 13.82 .793 17.46 12 13.200 .528 14.32 .733 19.56 .943 24.75 PVC PRESSURE PIPE Northern Pipe Products PVC AWWA C-905 PVC Water Transmission Pipe is manufactured from compounds conforming to cell classification of 12454B as defined in ASTM D-1784. The pipe meets the requirements of the AWWA C-905 standard specification for polyvinyl chloride water transmission pipe. The integral bell joint system meets the requirements of ASTM D-3139 and utilizes an elastomeric seal conforming to ASTM F-477. Northern Pipe Products AWWA C-905 Pressure Pipe for potable water carries the NSF Standard 61, the Canadian Standards Association Standard B137.3, the Underwriters Laboratories Inc Standard 1285, the Underwriters Laboratories of Canada Standard ULC/ORD-C1285, and the Factory Mutual Research Water Distribution Pipe for Underground Fire Protection Service marks of acceptance. The pipe is furnished in 20-foot laying lengths. The spigot ends are beveled and insertion depths are marked for correct installation. AWWA C-905
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Please contact our Webmaster with questions or comments.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||